Analyzes the sensor signals to determine how much cooking is taking place using a processor.
Kitchen hood temperature sensor.
Approximately 90 deg f per revolution.
Temperature sensors are located in the hood or in the exhaust duct often at its entrance.
This typically includes wiring the hood temperature sensors hood lights and wiring the fire suppression micro switches.
This is a ul listed quick seal fitting that s easy to install.
If the hood is provided with a control package it will need to be installed and wired by a licensed and certified electrician.
It has microprocessor based controls whose sensors automatically regulate fan speed based.
Detects cooking activity under the hood using sensors 2.
Kitchen hood outside air must be brought into the.
A kitchen hood exhaust hood or range hood is a device containing a mechanical fan that hangs above the stove or cooktop in the kitchen it removes airborne grease combustion products fumes smoke heat and steam from the air by evacuation of the air and filtration.
Includes temperature sensor and ul approved quick seal for hood penetration.
Hood options available to cover all temperature ranges.
Temperature interlock with standard switches.
Accurex offers a stand alone package as well as an option on our fan control center xfcc.
Accurex s temperature interlock is designed and installed to automatically activate the exhaust fan if not manually started whenever cooking operations occur.
The tel kitchen hood control vav system detects rises in smoke and temperature increasing the volume of air when it s needed.
10 amp at 120 vac.
If applicable see wiring diagram provided with the control package.
For questions please contact casservice at 1 866 784 6900 or supp.
Rated use temperature range.
The activation of the exhaust fan occurs through a temperature probe that detects an increased temperature and activates the fans.
Conventional kitchen hoods running at maximum design volume when turned on even if they re not needed.
Counter clockwise rotation to raise.
Casservice explains how to wire the temperature probes to an exhaust hood control package.
Current sensor installation instructions digital duct stat sensor installation pdf digital duct stat sensor installation acad drawing digital duct stat operation and installation manual fp option sensor installation pdf legacy fp option sensor installation acad drawing.
Use one sensor for any kitchen exhaust hood up to 120 inches long and two sensors for hoods greater than 120 inches.
For use when utilizing a single temperature interlock control on multiple hoods.
Heat sensor temperature sensor for commercial kitchen with a grease exhaust hood.
In commercial kitchens exhaust hoods are often used in combination with fire suppression devices so that fumes from a grease.